ex series - miuraboiler.ca

EX Series - miuraboiler.ca

2  · EX Gas/Oil Series - High Pressure Steam Boiler Miura’s exclusive “low water content, watertube” design is the most versatile boiler available in the marketplace today. A once-through, forced circulation steam boiler producing steam in just 5 minutes while maintaining an 85% fuel-to-steam efficiency.

Get a Quote
cleaver brooks nebraska nos-2a-67-hm 75,000 lb/hr …

Cleaver Brooks Nebraska NOS-2A-67-HM 75,000 lb/hr …

2019-3-1 · Boiler Feed Pumps: • Both Boilers are serviced by 2 x 100% Boiler Feedwater Pumps supplied by M-K Process. • Each pump is initially capable of supplying the full 206,000 lb/hr at the boiler required pressure. Burner: • The Boilers are equipped with dual gas/oil …

Get a Quote
cleaver-brooks | products & solutions | boilers

Cleaver-Brooks | Products & Solutions | Boilers

2019-10-11 · 10,000 to 500,000 lb/hr; Natural gas, #2 and #6 oil, alternative fuels, combination ; This rugged design has become the true workhorse of the rental boiler industry. The vertical gas outlet on the O-style puts the economizer above the boiler, minimizing the width of the overall package. Heavy Oil and Petrochemical Applications Brochure

Get a Quote
125-800 hp - cleaver-brooks

125-800 HP - Cleaver-Brooks

2018-8-5 · BOILER BOOK CBR 3 FEATURES AND BENEFITS † 125-800hp. † Steam and hot water. † Same available pressures as equivalent Model CB/CBLE/CBW/4WI. † Capable of firing natural gas, #2-#6 oil, bio-gas, digester gas or town gas.

Get a Quote
kg/h to lb/h converter, chart -- endmemo

kg/h to lb/h Converter, Chart -- EndMemo

Flow mass unit conversion between kilogram/hour and pound/hour, pound/hour to kilogram/hour conversion in batch, kg/h lb/h conversion chart. ENDMEMO.

Get a Quote
boiler capacity - engineeringtoolbox

Boiler Capacity - engineeringtoolbox

2020-3-6 · W = boiler capacity (Btu/h, kW) h g = enthalpy steam (Btu/lb, kJ/kg) h f = enthalpy condensate (Btu/lb, kJ/kg) m = steam evaporated (lb/h, kg/s) Boiler Horsepower - BHP. The Boiler Horsepower (BHP) is. the amount of energy required to produce 34.5 pounds of steam per hour at a pressure and temperature of 0 Psig and 212 o F, with feedwater at 0

Get a Quote
24 hour emergency boiler service- 718-373-3030

24 Hour Emergency Boiler Service- 718-373-3030

2019-11-11 · Gas Valves ,Thermal Coupling , Pilot Assemblies Programmable Thermostats Pressure Controls Manual Reset Pressure Controls Replaced Or Repaired Glass Gauge Assemblies Pressure Relief Valves Low Water Cut Offs (24v or 110v) Automatic Water Feeders (24v or 110v) Boiler Drain Valves Gas Burner Tubes Replaced Or Repairs Electronic Ignitions Spark Packs

Get a Quote
1,500 - 6,000 mbtu & 7,500-8,000 low water volume

1,500 - 6,000 MBTU & 7,500-8,000 Low Water Volume

2018-8-5 · range from 1.5 to 8 MMBtu/hr. The Model 5 Boiler is an excellent choice where high outputs are required but space LB/HR SHIPPING LBS 1500 1500 1200 35 1237 3100 to boilers rated at greater than 2.5 MMBtu/hr input on gas and 2.8 MMBtu/hr input on oil. Boilers that are labeled and tested in accordance with an independent

Get a Quote
industrial watertube boilers - cleaver-brooks

INDUSTRIAL WATERTUBE BOILERS - Cleaver-Brooks

2018-8-5 · 500,000 lb/hr Steam Natural gas, #2 and #6 oil, alternative fuels, combination Up to 1,500 psig Steam, temperatures to 1,050°F Available to <7ppm NOx* Ultra-Low CO get your boiler room online fast, firing natural gas or #2 oil. Capacities 10,000 to 225,000 lb/hr Design Pressure Up to 375 psig Steam Temperature Saturated Steam

Get a Quote
steam for power and process - babcock & wilcox

Steam For Power and Process - Babcock & Wilcox

B&W's radiant boiler designs accommodate pulverized coal, including difficult-to-burn coals, natural gas and/or oil and combustible byproduct gases. Subcritical pressures range usually 1800 to 2600 psi (12.4 to 17.9 MPa) and superheater and reheater outlet temperatures as required, usually in the range of 1000 to 1050 F (538 to 566C).

Get a Quote